Numerical will come on the basis of this slide, where we have to calculate the BOD for specific number of days.

this is series dilution, where we take one part from first sample add it in the 9 parts of water to dilute it more and more, we do dilution of sample water as to do the process faster as in industries time is very much the issue.

Ultimate BOD refers to the analysis of water sample for a period of longer duration it could be of 30 days, 60 days or so on…

Numerical
While doing numericals do them stepwise, mention units, write formulas as well to get full marks


Questions can also come like this
In a waste water treatment plant the BOD5 is 20% of that of UBOD that is 300 mg/l at 20 degree c where the k is 0.23 per day. Calculate the BOD6?
Erated - to supply (new word for me)
Toc analyzer cost around 16-17 lakh rupees